<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-06 19-26-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 63 dBuV VOLTAGE
Pilot RDS Phase Difference
6.6 kHz 4.3 kHz -13 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 71 kHz 4141 62,8109
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,3 dBr 7,85 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 19:26, 6.10.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (61 dBuV) Max at: 71 kHz MIN: 16 kHz % above 75 kHz: 62,8109 Acquired: 2025/10/06 19:25:39 Total samples: 4141 Equivalent time: 0:03:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 8,4 dBr MIN: 7,3 dBr AVE: 7,85 dBr % above 10,2 dBr: 0,0 Last value: 7,8 dBr (2025/10/06 19:25:39) Station: 96.90 MHz, signal: 4/5 (60 dBuV) 19:19 19:20 19:21 19:22 19:23 19:24 19:25 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality